logo

Your benefits at a glance

An extra-low patient positioning (patient surface height 28 cm) reduces the risk of injuries in case of a fall out of the bed, especially during the night.

Ergoframe® reduces the negative effects (shear, friction) of the pacient positioning and increases the patient´s comfort. It also decreases the risk of pressure ulcers in pelvic and back area spreading distance between back and tight rest up to 16 cm.

Extender offers 10 cm of extra  height of siderails. Increased height gives possibility to use the high active mattresses for enhanced pressure ulcers care.

Brake alarm automaticlly indicates unbraked bed and informs hospital staff about possible danger. This prevents the patient from falling caused by leaning against an unbraked bed when exiting or entering on the bed.

Double step locking mechanism of siderails protects from unintentional release.

Protector, located at foot end, adds the 100% covering of the mattress platform. The use of the Protector is recommended for clients who are diagnosed as confused or at extreme risk of a fall.

Technical features

External dimensions with 100 mm bumpers

219.6 cm x 109.8 cm
Mattress platform dimensions 200 cm x 100 cm
Maximum mattress height with single collapsible side rails 27 cm
Mattress platform height adjustment 28 – 80 cm
Maximum backrest angle 70°
Maximum thigh rest angle 34°
Trendelenburg/Anti-Trendelenburg position +14°/-14°
Ergoframe 16 cm
Safe working load 320 kg (image 3-b) | 265 kg (image 3 Standard, image 3-w)
Weight (depending on equipment) 168 kg

  • Height adjustment – motor
  • TR/ATR tilt adjustment – motor
  • Backrest adjustment – motor
  • Thighrest adjustment – motor
  • Calf rest  – manual
  • Bed extension – manual

Panel Supervisor, patient handset

Single collapsible siderails:

Image 3 Bariatric will be available only with single collapsible siderails with the height extender. Exceptional two steps release mechanism protects againist unintentional opening both medical staff and patient. Outstanding strenght and stability helps hospital staff to protect the patient.

  • Ergoframe with double retraction:  +16 cm
  • Special scissor construction provides reduced height of just 28 cm above floor level when 125 mm castors are used.
  • Central locking of all castors from 2 points
  • Central locking of all castors from 4 points (O)
  • 4 double castors 125 mm Tente Linea
  • 4 double castors 150 mm Tente Linea (O)
  • 4 castors 150 mm Tente Integral (O)
  • 5. roller for optimized driveability (optional)